EMC cable glands (Ex-eb gas & dust), single compression, for shielded cables, metal

E-VELA for Ex-e

• For applications in explosive environments.
• For Group II & III (Gas & Dust) - Ex-e only.
• For EMC applications.
• Can be used with intrinsically safe circuits.
• High quality strain relief and sealing, reliable performance for standard hazardous area applications.
• Up-to-date international approvals.

Clamping Range outer min
Clamping Range outer max
TL mm
D mm
Please click on the product image for more detailed PDF data sheets.

Info Outer Thread Size
(Male)
Clamping Range Outer Sheath
Ø min - max
mm
Clamping Range Seal Type Shield Diameter
Ø min-max
mm
TL
mm
SW Cap
mm
SW Body
mm
D
mm
H
mm
Part Number Compare
M8x1,25 2,0 - 4,0 Single 1,5 - 3,5 5,0 11 11 12,0 18,0 EBU0XSM
M16x1,5 4,0 - 8,0 Double 2,5 - 5,0 9,0 20 20 22,0 30,5 EBS01SM
M16x1,5 4,0 - 8,0 Double 2,5 - 5,0 9,0 22 22 24,5 30,5 EBS01M
M20x1,5 4,0 - 12,0 Triple 2,5 - 10,0 9,0 22 22 24,5 28,5 EBS1M
M25x1,5 10,0 - 18,0 Triple 8,0 - 14,0 9,0 28 28 31,0 32,0 EBS2M
M32x1,5 14,0 - 24,0 Triple 12,0 - 20,0 9,0 35 35 39,0 35,0 EBS3M
M40x1,5 22,0 - 32,0 Triple 18,0 - 28,0 9,0 45 45 49,5 42,5 EBS4M
M50x1,5 26,0 - 35,0 Triple 22,0 - 31,0 9,0 50 55 61,0 48,5 EBS5M
M63x1,5 35,0 - 45,0 Triple 31,0 - 41,0 9,0 64 68 75,0 45,0 EBS6M
M75x1,5 46,0 - 62,0 Triple 42,0 - 58,0 9,0 80 80 89,0 53,0 EBS7M
M90X1,5 60,0 - 75,0 Triple 56,0 - 71,0 9,0 95 95 105,0 57,0 EBS8M
M100x1,5 75,0 - 85,0 Triple 71,0 - 81,0 9,0 105 105 117,0 56,0 EBS10M
M110x1,5 85,0 - 95,0 Triple 81,0 - 91,0 9,0 115 115 128,0 58,0 EBS11M